MIL-B-48447A(MU)
DRAWINGS
U.S. Army, Frankford Arsenal
F8565556
Pressure Tester, Two-Station
Gage Interchangeability, Maximum
F11732109
Gage Interchangeability, Minimum
F11732110
Body Assembly
F11744900
Fixture, Alighment
F11746735
PACKAGING DATA SHEET
Packaging of Body Assembly: 11744900
11744900
(Copies of specifications, standards, drawings and packaging data sheets
required by suppliers in connection with specific procurement functions
should be obtained from the procuring activity or as directed by the con-
tracting officer.)
3.
REQUIREMENTS .
3.1 Fabrication. - The body assembly shall be manufactured in
accordance with Drawing F11744900 and drawings pertaining thereto.
3.2 Interchangeability. - The body assembly shall be capable of
insertion into and removal from Periscope: M35E1 (gages are specified
in lieu of periscope in 4.6.7.10).
3.3 General Specification.- The contractor shall be responsible for
adherence to, and compliance with the following requirements of specifica-
tion MIL-0-13830 and MIL-F-13926.
Order of precedence
a.
Dimensions and tolerances
b.
Inorganic protective surface finishes
c.
Part identification and marking
d.
e.
Workmanship
3.4 Environmentalo
3.4.1 Storage temperature. - The body assembly shall show no evidence
of cement separation, glass breakage or other physical failure, and shall
meet all the requirements of this specification at standard ambient tempera-
ture, plus 60 to plus 90" Fahrenheit (F), after having been exposed and
0
thermally stabilized at temperatures of minus 80 and plus 160 F.
3.4.2 Operating temperaturees. - The body assembly shall meet the
applicable requirements of 3.17 while exposed and thermally stabilized
at ambient of -40 and +150F.
3.4.3 Vibration "A". Vibration shall be applied along each of
three mutually. perpendicular axes of the body assembly. The vibration
shall be sinusoidal as follows: