|
| MlL-C-10082C(MU)
4.5.4 Classification of defects.
4 . 5 . 4 . 1 Canister, pa rticulate ~ M14 - assembly (Dwg M-3-876).
Acceptance standards
Defects
Categories
Critical:
4.6.2
DOP smoke penetration
1
4.6.4
Leakage
2
AQL 1.0 percent defective
Major:
Component missing
101
Component incorrect y
102
assembled
Threads (Table on Dwg
103
D5-3-876) Incorrect
Marking incorrect
104
workmanship
105
A Q L 0.25 percent defective
Maior A:
4.6.1
Airflow resistance
AQL 2.5 percent defective
Marking illegible
201
Protective finish missing
202
4.5.4.2 Preparation for delivery (sectIon 5).
Defects
Categories
None defined
Critical:
A Q L 2.5 percent defective
Maior:
Marking incorrect
101
Marking illegible
102
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |