MIL-C-11015E
3.4.3 Mounting hardware (when specified, see 3.1). Capacitors shall be furnished with the mounting hardware
specified (see 3.1).
3.5 Dielectric withstanding voltage. When capacitors are tested as specified in 4.7.2, there shall be no
breakdown or evidence of damage.
3.6 Barometric pressure (reduced) (qualification only). When tested as specified in 4.7.3, capacitors shall
withstand the dc potential specified (see 3.1) without flashover.
3.7 Insulation resistance. When measured as specified in 4.7.4, the insulation resistance shall be not less than
the value specified (see 3.1).
3.8 Capacitance. When measured as specified in 4.7.5, the capacitance shall be within the applicable tolerance
specified (see 3.1).
3.9 Dissipation factor. When measured as specified in 4.7.6, the dissipation factor shall not exceed the value
specified (see 3.1).
3.10 Shock, specified pulse (all styles except CK22 and CK27). When capacitors are tested as specified in 4.7.7,
there shall be no momentary or intermittent contacts of 0.5 millisecond (ms) or greater duration, open or short-
circuiting, or other indication of breakdown or arcing, nor shall there be any evidence of mechanical damage.
3.11 Vibration, high frequency. When capacitors are tested as specified in 4.7.8, there shall be no intermittent
contacts of 0.5 ms or greater duration, open or short-circuiting, or evidence of mechanical damage.
3.12 Thermal shock and immersion. When tested as specified in 4.7.9, capacitors shall meet the following
requirements:
Visual examination-----------------------------No mechanical damage. Marking shall remain legible.
Dielectric withstanding voltage
(when specified; see 3.1)------------------As specified in 3.5.
Insulation resistance---------------------------Not less than value specified (see 3.1).
Capacitance
(when specified; see 3.1)------------------Capacitance change shall not exceed 10 percent of the initial
measured value.
Dissipation factor
(when specified; see 3.1)------------------As specified in 3.9.
3.13 Salt spray (corrosion) (styles CK70, CK72 and CK80). When capacitors are tested as specified in 4.7.10,
there shall be no harmful or extensive corrosion, and at least 90 percent of any exposed metal surface of the
capacitor shall be protected by the finish. There shall be no mechanical damage to insulating surfaces. In addition,
corrosion of the mounting hardware or of the terminals shall not exceed 10 percent of the surface area.
3.14 Terminal strength (when specified; see 3.1). When capacitors are tested as specified in 4.7.11, the
terminals shall not loosen or rupture.