| ![]() MIL-C-24757(SH)
TABLE I. Physical requirements.
Characteristics
Requirements
Weight ounce/square yard (minimum)
6.6
best cloth (minimum)
finished cloth (maximum) 8.6
(gram/square meter)
Yarns per inch (centimeter (cm)) (minimum)
warp
(minimum) 38
Filling
(minimum) 38
Breaking strength pounds (newtons) (minimum)
warp
(minimum) 250
Filling
(minimum) 250
Tearing strength pounds (newtons) (minimum)
(minimum) 7.86 (35)
Warp
Falling
(minimum) 7.86 (35)
Flame resistance (warp and filling)
(maximum) 20
Flaming time, seconds (maximum)
(maximum) 3.0
Glow time, seconds (maximum)
( maximum) 1.0
Char length, inches, cm (maximum) average
2
0 leakage
Hydrostatic sign (25 16/in )
Air permeability
(maximum) 0.0
Abrasion (minimum cycle)
Bar No. 15, 5 lb flexing bar load, 2.5 lb
(minimum warp) 50
Pressure plate load
(minimum filling) 50
4. QUALITY ASSURANCE PROVISIONS
4.1 Responsibility for inspection. Unless otherwise specified in the contract or purchase order
the contractor is responsible for the performance of all inspection requirements (examinations and
tests) as specified herein. Except as otherwise specified in the contract or purchase order, the
contractor may use his own or any other facilities suitable for the performance of the inspection
requirements specified herein, unless disapproval by the Government. The Government reserves
the right to perform any of the inspections set forth in this specification where such inspections
are deemed necessary to ensure supplies and services conform to prescribed requirements.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |