| MIL-C-38418E(AS)
e.
Reposition the azimuth detector to 10.
Note the deflection of the sync indicator pointer on the
f.
controller. The sync indicator pointer on the controller shall be at
negative (-) full scale.
Measure ac voltages at the tabulated pins of
connector
g.
(2J2). Voltages shall be within the following limits:
2J2 Pins
volts
7 to 9
26 1Vac
7 to 12
89 2Vac
h.
Set the decade resistor to 5,000 ohms.
(1)
The voltage from connector 2J2-7 to 2J2-9 must become
6.5 1Vac.
(2)
For the ASK-32/A24G-39 the sync indicator pointer on
the controller shall become centered within 1/16 inch.
(3)
For the ASK-44/A24G the sync indicator pointer on the
controller shall remain at negative (-) full scale.
i.
Set the decade resistor to 8,000 ohms.
(1)
The ac voltage
from connector 2J2-7 to 2J2-9 must
return to 26 1Vac.
(2)
For the ASK-32/A24G-39 the sync indicator pointer on
the controller shall return to negative (-) full scale.
(3)
For the AsK-44/A24G the sync indicator pointer on the
controller shall remain at negative (-) full scale.
4.6.4.14 Roll Erection and Slaving Control
4.6.4.14.1
ASK32/A24G-39 Electronic Control Amplifier - The roll
erection and slaving control for the ASK32/A24G-39 shall be checked as
follows:
a.
Set the controls on the controller and the electronic control
amplifier as follows:
66
|