| MIL-C-38418E(AS)
Mode switch to SLAVED
Latitude control to 0
Hemisphere switch to N
Compensation switch to OFF
b.
Position the azimuth detector to O.
Depress and hold the heading
set control knob on the
c.
becomes
controller until the indicated servoed
repeater heading
synchronized with the azimuth detector.
d.
Reposition the azimuth detector to 340.
The
e.
Measure the dc voltage from connector 2J2-17 to 2J2-18.
dc voltage shall be greater than 8.OVdc.
Measure ac voltages at the tabulated pins of connector 2J2.
f.
Voltages shall be within the following limits:
Volts
(2J2) Pins
8 to 9
6.5 1Vac
8 to 12
108.5 2Vac
Rotate the displacement gyroscope heading transmitter at a
g.
rate of 3 per minute for 1.5 minutes.
(1)
The voltage from connector 2J2-8 to 2J2-9 shall remain
at 6.5 1Vac.
(2)
The voltage from connector 2J2-17 to 2J2-18 shall
remain greater than 8Vdc.
h.
Repeat step g with a rate of -3 per minute for 1.5 minutes.
4.6.4.14.1.1 Switching Rate - The switching rate shall be checked as
follows.
(Note:
During steps b through d, the dc voltage may
temporarily become less than 1Vdc while the switching rate is applied.
The time at which this occurs shall not be recorded.)
a.
Set the controls on the controller and the electronic control
amplifier as follows:
67
|