| ![]() MIL-C-45010A
AMENDMENT 6
the batch represented by the sample shall be rejected. All
batches produced between the time that the last batch was
tested and accepted and the batch which failed shall be
tested in accordance with the applicable methods given in
paragraph 4.3. If any of these batches fail to meet any of
the test requirements, that batch shall also be rejected.
In addition, after any failure of a batch the contractor
will return to 100% inspection until "i" successive batches
are accepted as required by MIL-STD-1916."
4.3.1
Delete in its entirety and substitute:
"4.3.1 Moisture. The moisture shall be determined in
accordance with MIL-STD-650, Method 101.4 or an approved
equivalent method. (see 6.9)"
4.3.2.1.1 Titration Method, delete "carbon tetrachloride"
wherever it appears and substitute "aliphatic naphtha (No.
49). (see 6.8)"
PAGE 5
4.3.2.1.2 Gravinetric Method, delete "carbon tetrachloride"
whereever it appears, and substitute "aliphatic naphtha
(No. 49). (see 6.8)"
4.3.2.1.3 Delete in its entirety.
(Paragraph 4.3.2.1.3 was
added in Amendment 2).
4.3.2.2
Polyisobutylene binder, add the following new
paragraph:
"4.3.2.2 Polyisobutylene binder. The percent of
polyisobutylene binder shall be calculated on a dry basis by
subtracting from 100 percent the percent of RDX as obtained
in 4.3.2.1."
6
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |