| MIL-C-45574B(AR)
TABLE II. Classifiication of and inspection method for defects.
Inspection method
Defect
Category
Major
Visual
Illegible or incorrect marking
101
Visual
Improper level of preservation, packaging
102
or packing
Visual
Inadequate cleaning or drying
103
Visual
Improper preservation application
104
Visual/Manual
Improper or inadequate blocking and bracing
105
Visual/Manual
Improper closure or strapping of containers
106
Minor
Visual
Workmanship
201
5. PACKAGING
5.1 Cannon - Levels A, B and C. Cleaning, drying, preservation, unit
packaging and packing of cannon shall be in accordance with the requirements
of Packaging Data Sheet (PDS) P11578068, P11578233, and MIL-P-14232 for the
level of protection specified in the contract (see 6.2).
5.2 Repair parts - Level A, B and C. Cleaning, drying, preservation, unit
packaging and packing of repair parts shall be in accordance with the
applicable repair part PDS and MIL-P-14232 or the applicable repair part SPI
and MIL-STD-2073-1 for the level of protection specified in the contract (see
6.2). When Level C requirements are not shown on the PDS/SPI, Level C
packaging shall be in accordance with MIL-STD-1190.
5.2.1 Level X - Industrial packaging. Cleaning, drying, preservation, unit
packaging and packing of repair parts shall be in accordance with ASTM 03951
when industrial packaging is specified in the contract (see 6.2).
5.2.1.1 Quantity in Unit Package (QUP). When industrial packaging of repair
parts is specified in the contract, the QUP shall be the same as specififed in
the contract (see 6.2).
5.3 Marking of packages.
5.3.1 Levels A, B and C. Marking of the unit package, intermediate packages.
and exterior shippinq containers shall be in accordance with MIL-STD-129.
When specified (see 6.2), bar code marking shall be in accordance with
MIL-STD-129 and MIL-STD-1189.
14
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |