| MIL-C-46344A(MU)
checked on any of the 4 cams within the computer. A maximum of 8 changes
in direction of the servo motor, as a settling out action, shall be con-
sidered as satisfactory operation. These 8 changes may be counted as
clicks.
3.5.5 Component operation.
3.5.5.1 Operational values.- The operational values shall not exceed
the values given in Table IV at temperatures indicated.
TABLE IV
OPERATIONAL VALUES
3.5.5.2 Time of response.- At standard ambient temperature (plus
60 to 90 degrees Fahrenheit), with the output shaft load as specified in
paragraph 3.5.2 applied, the inner and outer indexes positioned as specified
in Table "V, and the ammo selector set on the ADPS-T, M392, the outer index
shall stabilize on the inner index within the elapsed time specified,
after power has been applied.
7
|