| ![]() MIL-C-50736(MU)
8 August 1973
3.3.1.1 Returns and range readout selection logic. with the
digital Type-A signal (item 2.1) of table I applied as specified in
table II, the displays shall be as specified in table II.
3.3.2 Environmental.
3.3.2.1 Storage temperature. The assembly shall meet the
requirements of 3.3.1 at ambient temperature after exposure to and
thermal stabilization at -80F and +160F.
3.3.2.2 Operating temperatures. The assembly shall meet
the requirements of 3.3.1 while exposed to and thermally stabilized
at -40F and +125F, subsequent to which the requirements of 3.3. 1
shall be met at ambient temperature.
3.3.2.3 Vibration. The assembly shall show no physical
failure and shall meet the requirements of 3.3.1 after being exposed
to the following vibratory conditions:
1/64 inch, constant
a. Amplitude:
(1/32 inch double amplitude)
b. Vibratory motion:
Simple harmonic
c. Sweep time:
5 to 55 to 5 Hertz in a
five-minute period
Three linear or logarithmic
d. Vibration cycling:
sweeps applied to each of the
three mutually perpendicular
axes.
4
|