| ![]() MIL-C-50740(MU)
8 August 1973
temperature change during cycling not greater than 8F per minute. At
each of the specified operating temperatures, perform the tests of 4. 6.2
through 4. 6.7 to determine compliance with 3.3.2.1 and 3.3.2.2.
4.6.8.2 Vibration test. Perform this test utilizing the apparatus
specified in method 514.1 of MIL-STD-810 and in accordance with part I
of procedure I therein, except that the vibratory conditions of 3.3. 2. 3
shall apply. Following vibration exposure, examine the assembly for
structural failures, loose hardware, wire breakage, and abrasion.
Perform the tests of 4.6.2 through 4.6.7 to determine compliance with
3.3.2.3.