| MIL-C-52037F(ME)
3.2
Unless otherwise specified (see 6.2), a sample shall be
subjected to first article inspection (see 6.3) in accordance with 4.3.
3.3 Material. Material shall be as specified herein. Materials not specified
shall be selected by the contractor and shall be subject to all provisions of
this specification.
3.3.1 Material deterioration prevention and control. The compressor shall be
fabricatd from compatible materials, inherently corrosion resistant or treated
to provide protection against the various form of corrosion and deterioration
that may be encountered in any of the applicable operating and storage
environments to which the compressor may be exposed.
3.3.2 Dissimilar metals. Dissimilar metals shall not be used in intimate
contact with each other unless protected against galvanic corrosion Dissimilar
metals and methods of protection are defined and detailed in MIL-STD-889.
3*3*3 Identification of materials and f fishes. The contractor shall
identify the specific material, material finish or treatment for use with
component and subcomponent and shall make information available upon request to
the contracting officer or designated representative.
s. For the purpose of this requirement, recovered
3*4
materials are thee materials which have been collected from solid waste and
reprocessed to become a source of raw materials, as distringuished from virgin
raw materials. The components, pieces and parts incorporated in the compressor
may be newly fabricated from recovered materials to the maximum extent
practicable, provided the compressor produced meet another requirements of
this specification. Used, rebuilt or remanufactured components pieces and
parts shall not be incorporated in the compressor.
3.5
The compressor shall operate as
3.5.1 Operation at extreme temperatures.
specified herein under the following renditions.
3.5.1.1 Low temperatures The nonwinterized compressor shall start and
operate as specified herein for not less than 2 hours at rated capacity in
With a winterization system installed and
ambient temperature at -25
operating the compressor shall start and operate as specified herein for nut
less than 2 hours at rated capacity in ambient temperature -50 `F (see 3.17) .
6
|