MIL-C-52037F(ME)
spring-loaded valve shall be provided between the bleed valve and
to prevent dirt and moisture from entering the hose assembly when
relieved.
3.11
All surfaces requiring lubrication shall be
a means of lubricating.
3.11.1 Lubricants. The procedure for the selection of lubricants shall be in
accordance with MIL-STD-838, section 5.  Lubricants selected shall be in
accordance with MIl-HDBK-113, chapter 2.  When the specified of the
lubricant selected includes a requirements for a Qualified Products* (QPL),
the lubricant supplied shall be from a source that is listed on the applicable
QPL (see 6.4).
3.11.2 Lubrication fittings.  Lubrication fittings shall conform to
MIL-F-3541, type I, II or III. " Fittings shall be located in protected positions.
Fittings shall be accessible to a grease gun conforming to MIL-G-3859, type II.
Accessibility to fittings shall be provided without the removal or adjustment of
accessories or parts.  Panels and plates equipped with hand-operable, quick-
,
disconect fasteners may be removed to provide accessibility to lubrication
fittings.
device.  A pressure-release device shall be provided
3.11.3
where the use of pressurelubrication equipment will damage grease seals or
other parts.
of lubricant  Enclousres, such as
3.11.4  Enclosures with internal
gear cases and transmission housings which contain a reservoir of lubricants for
lubrication of the parts enclosed, shall be equipped with dipsticks, check plugs
nut less than 1/2-inch pipe size, or sight gauges to determine the level of the
lubricant. Each enclosure shall be equipped with a drain plug. Each enclosure
shall reequipped with a means for filling the enclosure with lubricant. The
drain plug shall be located so that removal of the drain plug will result in
complete drainage of the lubricant f- the enclosure.  Drain outlets shall be
located to allow lubricant to drain to a suitable container when the compressor
ins in its normal position.  Integral tubes or troughs may be used to convey
drained lubricants from the drain plug to the drain outlet. Accessibility to the
drain plug, the filling means, and the lubricant-level checking device shall be
obtained without the removal or adjustment of accessories or parts. Housing side
panels and plates equipped with hand-operable, quick-disconnect fasteners may be
removed to facilitate this  accessibility.
3.11.5 Delivery lubrication service  When delivered, all components, except
those for which preservatives are specified in 5.1, shall be lubricated. Grease
lubrication, excludig lubrication of sealed bearigns, shall be with grease
conforming to MIL-G-10924 or other grease specifications listed in MIL-HDBK-113.
Unless otherwise specified herein, all components shall be filled to the
operating level with military oils designated for use in the temperatures range as
specified herein. Each lubricated component  shall  be  tagged  ina  conspicuous
place to indicate the temperature range and grades of oils and greases used.
Oil dilution for starting and running the compressor at
3.11.6 Oil dilution.
low outside ambient temperature shall not be acceptable.