MIL-C-64025(AR)
3.6.14.1.3 Data output sequence.  When the load of Figure la is
placed on the RCU MCD coil as specified, an RCD pulse sequence shall
be generated at the output of the load as specified in Figure 2 in
response to a COPY command when tested per 4.5.2.12
3.6.14.1.4 Data output completion display. When the RCU has
completed transmission of the RCD pattern over the MCD coil, the RCU
shall display the four digit SEND code associated with that pattern as
specified by Drawing 9333026 when tested per 4.5.2.12
3 .6.14.2 RCD code receive.
3,.6.14.2.1 Receive  input Prompt
When the RCU is in the STORE
q
mode and the MCD coil is driven as specified by Figure 3a the RCU
shall display ",RECEIVE" when tested per 4.5.2.13
3 . 6 . 1 4 . 2 . 2 R e c e i v e i n p u t a c c e p t a n c e .  When the TRANSFER key is
pressed while the RCU displays  "RECEIVE", the RCU shall display the
four digit SEND code associated with the-RCD pattern of Figure 3 as
specified by Drawing 9333026 when tested per 4.5.2.13
SEND mode.
3.6.15
Initial group status display.
1f a SEND code has been
3 .6.15.1
previously selected and correctly keyed in within the first 15 seconds
after the unit power switch has been turned on, the RCU shall display
"n CMD", where n is the GROUP ID (set to 1 on entering the SEND mode)
NONE,  TRANSFER, DEPLOY, RESET SD, or DESTRUCT
and CMD is one of:
when tested per 4.5.2.15
3.6.15.2 Invalid SEND code entry.  The RCU shall display
INVALID" 16 + 1.0 seconds after the unit power switch is turned on if
an incorrect or incomplete SEND code or no entry is keyed in on the
keyboard within the first 15 seconds after the unit power switch is
turned on when tested per 4.5.2.14
3.6.16  Display timeout .  The RCU shall blank the display in the
SEND or STORE mode after 10 + 1.0 seconds of keyboard inactivity when
tested per 4.5.2.9
3.6.17 G r o u p selection.
The RCU shall provide the capability to
control up to 15 addressed groups. Control shall be exercised on each
group individually or on all 15 groups simultaneously. Group selection
is made while in the SEND mode. Pressing the GROUP ID key shall
increment the current GROUP ID number of the RCU by one. GROUP ID's
will be the numbers 1 thru 15 and ALL when tested per 4.5.2.17
3.6.18  Group status display.  The RCU maintains in memory the
current status of each group and displays that status while in the
SEND mode. The status format shall be "n status", where n is the GROUP
ID number 1 to 15
inclusive  and status is one-of: NONE, TRANSFER,
DEPLOY, RESET SD, DESTRUCT and "ALL", for the GROUP ID of ALL.