Click here to make tpub.com your Home Page

Page Title: Power off current test.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-C-64025
Open
Col 2
A2-E53
Col 3
Open
A2-E54
Col 4
Open
A2-E55
Open
S.c.s.
A2-E38
XMIT
Open
A2-E39
0+0.2V
CLEAR
A2-E42
0+0.2V
VREFL
A2-E58
4.5.7.6  Power off current test.   M e a s u r e t h e c u r r e n t i n t o
A2-E45
(RAMV) and verify Compliance with the requirements of 3.9.3.
I
Memory retention voltages  Measure the voltage at the
4.5.7.7
cathode of CR2 of the AZ assembly and verify compliance with the
requirements of 3.9.6.
4.5.7.8 Power on clear.  Open A2-E42 (CLEAR) then apply 13+0.5
q
volts to A2-E34 (+15V). Verify that the waveform response at A2-E29
(CLR) is in compliance with the requirements of 3.9.8.1.
I
a p plication test.
Verify that the SENDER
4.5.7.9 Initial
power
"INVALID" in compliance with the requirements of 3.9.9. If
dis- lays
p
I
the RCU displays `-'ON", short the cathode of CR2 of the A2 assembly to
A2-E43 (GND) and restart testing at this point.
I
4.5.7.10  STORE code entry Prompt .  Open the supply connection to
A2-E34 (+15V). APPlY  0+0.2 volts to A2-E42- (CLEAR). Execute the  -
following sequence: Apply 0+0.2 volts to A2-E38 (S.C.S.), Open A2 E42
(CLEAR), apply 13 + 0.5 volts to A2-E34 (+15v), wait at least 1
second, open-- A2-E38 (S.C.S.). Verify that the SENDER displays five
dashes (--- ) in compliance with 3.9.10.1.
4.5.7.11  STORE code select test.  Enter keys 1 thru 8
sequentially. Verify the display response with the requirements of
3.9.10.2.  Enter keys 1 thru 5 sequentially. Verify that the SENDER
displays "12345".
Open A2-E34 (+15V). APPlY 0+0.2
Keyboard timeout test.
4.5.7.12
Volts to A2-E42 (CLEAR) for at least 1 millisecond then open. Apply
13+0.5 volts to A2-E34 (+15V). Verify that the SENDER displays "ON" in
compliance with the requirements of 3.9.8.1. Measure the time-lapse
from the moment power is applied to A2-E34 (+15V) until the SENDER
displays "INVALID" and verify compliance with the requirements of
3.9.11 .4."
Processor reset test.  Apply 0.0+_0.2 volts to A2-E42
4.5.7.13
(CLEAR) for at least 1 millisecond, then open. Verify that the display
reads "ON" in compliance with the requirements. of 3.9.8.2. OPen the
supply-connection to A2-E34 (+15v).
4.5.7.14 Invalid STORE code entry test.  Apply 0+0.2 volts to
A2-E42 (CLEAR) for at least 1 millisecond then open. Apply 13+0.5
volts to A2-E34 (+15V). Enter "12344" (an incorrect STORE code) within
the next 15 seconds after application of power to A2-E34 (+15V).
Verify that the SENDER displays "INVALID" in compliance with the
requirements of 3.9.11.4. Open the supply connection to A2-E34 (+15V).
.
.