| ![]() MIL-C-64025
that the battery low indicator flashes as specified in 3.9.2.
verify
Set the supply voltage to 13+0.5 volts.
4.5.7.34 Data retention test. Open the supply connection to A2-
E34 (+15V). Apply 0+0.2 volts to A2-E42 (CLEAR) for at least 1
millisecond, then open. Apply 13+0.5 volts to A2-E34 (+15v) and enter
"12345" in the next 15 seconds. Enter the COPY key followed by the
TRANSFER key. Note the RCD code. Open the supply connection to A2-E34
(+15V) and A2-E45 (RAMv). Wait 315+15 seconds. Apply 13+0.5 volts to
A2-E45 (RAMV). Apply 1+0.2 VOlts to A2-E42 (CLEAR) for at least 1
millisecond, then open, Apply 13+0.5 volts to A2-E34 (+15V) then enter
"12345" in the next 15 seconds. Enter the COPY key followed by the
TRANSFER key. Verify that the RCD) code is the same as noted prior to
disconnecting the supply. Open A2-E34 (+15v). Apply 0+0.2 volts to A2-
E42 (CLEAR) for at least 1 millisecond, then open. Apply 13+0.5 volts
to A2-E34 (+15V) then enter the SEND code from 4.5.7.31 within the
next 15 seconds. Step thru each group status and verify that each
group has retained the status prior to disconnecting the supply.
5. PACKAGING
5.1 Preservation . .and packaging
........ ..
Preservation and packaging shall be in accordance
5.1.1 Level A.
with drawing 9362585.
5.2 Packing
Packing shall be in accordance with drawing
5.2.1 Level A.
9362584.
5.3 Marking
Marking shall be in accordance with drawing
5.3.1 Level A.
--
9362584 and 9362585.
5.4
Consolidation
5.4.1 Level A.
Consolidation shall be in accordance with drawing
8808362.
5.5
Unitization
5.5.1.
Level
A.
Unitization shall
be
in
accordance
with
MIL-sTD-1169.
6. NOTES
6.1 Ordering data.
See MIL-A-48078.
6.2 Submission of inspection equipment designs for app roval.
(See MIL-A-48078) Submit equipment designs as required to: Commander,
U.S. Army Armament Research, Development and Engineering Center
(ARDEC), Attn: AMSMC-QAT-I(D), Dover, N.J. 07801-5001.