| MIL-C-70495(AR)
Common connector
8.
4.6.4
3.2.1.8
contact continuity
4.6.1
3.3.2
ESS temperature
9.
4.6.2
3.3.3
ESS vibration
10.
MAJOR:
AQL 1.0% Defective
4.6.5
3.6
Workmanship
101.
4.4.2 Special sampling. One supply shall be selected at
random as a special sample from each lot or each 100 produced
The sample shall meet the requirements
which ever occurs first.
and tests in Table 111.
Classification of defects.
TABLE 111.
Test
Procedure
Requirement
Characteristics
No.
Applicable
Drawing/
3.4
Fabrication
201.
Visual
Applicable
Drawing/
3.7
Materials
202.
Visual
The tests in Table III shall be conducted at room ambient
Note:
temperature (as specified in 3.3.1).
Should any one item of a special
4.4.3 Failure of sample.
sampling fail to meet the specified test requirements, acceptance
of the represented inspection lot will be suspended by the
Government until necessary corrections have been made by the
contractor and resubmitted items have been approved in accordance
with "Acceptance and Rejection" as specified in MIL-STD-105.
Except as otherwise provided for
4.5 Inspection equipment.
by the contract, the contractor shall supply and maintain
inspection equipment in accordance with the applicable
requirements of MIL-I-45607.
4.5.1 Government furnished inspection equipment. Where the
contract provides for Government furnished test equipment. Supply
and maintenance of test equipment shall be in accordance with the
applicable requirements specified in MIL-I-45607.
4.5.2
Contractor
furnished
inspection
equipment.
4.5.2.1 Government design. All inspection equipment
specified by drawing number In specification or QAP forming a pa
of the contract shall be supplied by the contractor in accordance
with technical data included in the Technical Data Package List
(TDPL).
7
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |