| ![]() MIL-C-70725A (AR)
4.3.3 Inspections to be performed. See MIL-A-48078 and
Table I. Examination for critical, major and minor defects shall
be performed in accordance with Table I. The sample to be
examined shall be drawn in such a way that it is representative
of the entire quantity submitted. Nonconforming cartridges shall
be rejected and put aside for further examination. Disposition
instructions for nonconforming cartridges shall be provided by
the contracting officer.
4.3.4 Rejection. See MIL-A-48078. The qualification
sample shall be rejected if any one of the following occurs:
a. The qualification sample fails to conform with the
applicable drawings and requirements of Tables I and IV.
b. The materials and process techniques utilized to
manufacture the sample could not be applied in normal production.
The equipment utilized to manufacture the sample
does not represent the equipment to be used in normal production.
4.3.5 Basis for qualification. Contractors that meet all
of the qualification requirements will be placed on the qualified
vendor's list. The vendor shall remain on the list as long as
the same design and materials are used.
12
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |