| MIL-D-16196E(SH)
10 percent of special tubes for heat exchanger (if included in the
(g)
design), including tube packing.
1 ammeter of each size and type.
(h)
(i)
Repair parts for motors, controllers, switches, and relief valves
should be furnished in accordance with the requirements of the
applicable specifications for such components.
----
10 percent of compression type heat exchanger tube fittings (if
(j)
used) .
(k)
Repair parts for feedwater pressure and flow regulating valve.
Phenolic tube plugs to plug 10 percent of evaporator tubes.
(1)
The packaging requirements of
6.7 Sub-contracted material and parts.
referenced documents listed in section 2 do not apply when material and parts
are acquired by the contractor for incorporation into the equipment and lose
their separate identity when the equipment is shipped.
As used herein "drawing review activity" is
generally a Government command or agency such as NAVSEA, or an authorized
Communication with the drawing review activity should be handled
representative .
through the contracting activity.
Any exception to 3.2.6 must be approved by
6.9 Lubricants and compounds.
NAVSEA.
6.10 NAVSEA ap proval .
NAVSEA approval is required for any exceptions to
3.4.2.1.1, 3.4.2.1.2 and 3.4.2.2.
6.11 Subject term (key word) listing.
Electric immersion heater
Flow control
Flow meter
Rotameter
Totalizing meter
Marginal notations are not used in this
6,12 Changes from previous issue.
revision to identify changes with respect to the previous issue due to the
extensiveness of the changes.
Preparing activity: