Click here to make tpub.com your Home Page

Page Title: Discharge hose (Drawing 116-3-61).
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-D-51453A(EA)
(1)
D i s c h a r g e hose (Drawing 116-3-61).
Defects
Categories
None defined
Critical:
AQL 1.0 percent defective
Major:
Components incorrectly assembled
101
Hose assembly length incorrect
102
End fittings not as specified
103
Date of manufacture missing
104
Service life tag missing or incorrectly dated
105
106
Quick disconnect couplings class or end style incorrect
.
107
Workmanship (3.10)
AQL 4.O percent defective
Minor:
Finish on end fittings missing or incorrect (applies to
201
steel fittings only)
Finish on coupling missing or incorrect
202
(m) Packaging (section 5).
Defects
Categories
None defined
-Critical:
AQL 4.0 percent defective
Major:
101
Components or repair parts missing
Components  and repair parts not cleaned and dried as
102
specified
103
Preservation missing
104
Packaging method incorrect
105
Container incorrect
106
Containers closure incorrect.
107
Container or package damaged
108
Marking missing or incorrect
109
Strapping loose or missing
4.4.4 Tests.
Tests shall be conducted as follows:
4.4.4.1 Functioning.
Connect a test gage between the low pressure pneumatic
hose and the quick-disconnect at the regulator outlet.  Charge the high pres-
sure cylinder to 2100 + 100 psig air, and connect it to the disperser.  slowly
open the high pressure valve.  Record the regulator outlet pressure when needle
has stabilized.  Using a suitable leak-detecting solution, check all joints for
11

Privacy Statement - Press Release - Copyright Information. - Contact Us