3.5.3.1.3 Density selections, The dispenser shall be capable
of providing six (6) distinct densities as specified in TABLE IV.
TABLE IV - Mine Densities
DENSITY
SELECTION
One (1) mine per
0.001
1
thousand square meters.
Five (S) mines per
0.005
2
thousand square meters.
Seven (7) mines per
0.007
3
thousand square meters.
Ten (10) mines per
0.010
4
thousand square meters.
Twenty-five (25) mines
0.025
5
per thousand square
meters.
Maximum reel rate at two
Max.
6
(2) mines per second.
A tolerance of +75% - 10% is allowed on density
NOTE:
selection Number 1. The other density selections are
allowed a 10% tolerance.
3.5.3.1.4 Jog mine spacinq. The dispenser shall be capable of
providing six (6) density selections in jog position as follows:
TABLE V - Mine Separations
SEPARATION
DENSITY
SELECTION
(Meters between mines)
10
0.001
1
9
0.005
2
8
0.007
3
7
0.010
4
6
0.025
5
2 Mines/Second
Max.
6
NOTE:
A 10% tolerance is allowed on the above separation
requirements.
3.5.4 Environmental. An environmental test shall be performed
on selected dispensers as specified in Table VIII. See 6.2).
3.5.4.1 Temperature. Utilizing components permanently mounted
and furnished with the dispenser, the engine shall start within five
(5) minutes and the dispenser shall operate under full-load
conditions within fifteen (15) minutes after engine start0 in any
0
0
ambient temperature from minus 25 F (minus 30 C) to +125 F
(52C).