| MIL-D-70484(AR)
TABLE III. Display unit connector J1 (cont'd).
3.4.3.1.3 Operational control. The DU shall control the
operation of the four OU's through a twisted pair serial data line
as defined by the DU/OU Interface Specification, 9324400. The
operations include taking inventory, conducting self-test,
charging fuzes, and firing rockets.
3.4.3.1.4 Accuracy. The accuracy for both the manual and
automatic setting modes, excluding fire control errors shall be
1 millisecond in the data sent to the OU's.