| MIL-D-70789A (AR)
additional cycles, any of the calculated values exceed the stated
specification, the unit shall be rejected and after
adjustment/repair subjected to the entire random vibration and
temperature sequence.
Quality conformance inspection.
TABLE VIII.
TEST METHOD
REQUIREMENT
PARAGRAPH
PARAGRAPH
CHARACTERISTIC
NO.
100% Inspection
4.8.1
3.5, 3.8 & 3.10.1
Physical Examination
1.
4.8.2.1
3.7.12
ESS-Vibration
2.
4.8.2.2
3.7.1.4
ESS-Temperature
3.
4.8.3
3.5, 3.6, 3.8,
4.
Quality Verification Test
3.10, 3.11
Major
4.8.5.11
3.7.7
Washdown
1.
*Characteristics listed as major shall be tested using a sample
of one unit selected randomly from each month's production or
one from each 50 units produced, whichever occurs first.
4.8 Method of inspections.
4.8.1 Physical examination. The equipment shall be
examined for the following defects:
a. Configuration not as specified. Configuration
record incomplete or inaccurate.
Assemblies, parts or components missing or not as
b.
specified
Materials not as specified.
c.
Safety devices missing or not as specified.
d.
System interfaces not as specified.
e.
Treatment and painting not as specified.
f.
Workmanship not as specified.
g.
h.
Assembly incomplete or incorrect.
103
|