| MIL-F-11673F(EA)
wood preservative conforming to composition B of TT-W-572. Prior to packing the
cans into the treated shipping container, the container shall meet the dryness-
of-preservative requirement specified in MIL-B-2427. The inside dimensions of
the container shall be approximately 15 by 13-1/4 by 8-3/8 inches (length, width
and depth respectively). The 30 cans of fuzes shall be packed in the container
Fiberboard pads fabricated from material conforming
i n 2 tiers of 15 per tier.
to type CF, class weather resistant, variety SW of PPP-F-320 shall be used
between the contents and the sides, ends, top and bottom of the box; and between
the 2 tiers of canned fuzes. Additional pads shall be used as required to make
a tight pack. A l s o , each tier in the box shall De fitted with interlocking
slotted fiberboard partitions made from the same material as the fiberboard
pads. Closure of the container shall be in accordance with the requirements of
the applicable container specification and its appendix using galvanized strap-
ping.
5 . 2 . 2 Level B. Fuzes shall be packed in accordance with 5.2.1 except the
wood preservative is not required.
5 . 2 . 3 lnterplant shipment (see 6.4). The quantity of fuzes specified in the
contract or order (see 6.2) shall be prepared for shipment in containers which
comply with the Code of Federal Regulations and the rules and regulations appli-
cable to the mode of transportation. Shipping containers shall assure safe
Interplant shipment
delivery to destination without damage to the contents.
pack shall not be shipped on Government Bill of Loading (GBL).
5 . 2 . 4 Unitized loads. When specified in the contract or order, level A and
B snipping containers shall be palletized in accordance with Drawing 19-48-4116,/
100AR1.
5 . 3 Marking.
5.3.1 Levels A and B. Marking shall be in accordance with MIL-STD-129. In
addition to any specific marking required by the contract or order, unit packs
shall be marked in accordance with Drawing 36-3-114. Shipping containers shall
be marked in accordance with Drawing 36-7-44.
5 . 3 . 2 Interplant shipment (see 6.4). Containers shall be marked in accor-
dance with FED-STD-123 and the Code of Federal Regulations.
NOTES
6.
This item is used in burning-type munitions.
6.1
Intended use.
Acquisition documents should specify the following:
6.2
Ordering data.
( a ) Title, number and date of this specification.
(b) Level of unit packing and packing required (see 5.1 and 5.2).
( c ) Quantity required for interplant shipment (see 5.2.3).
8
|