| MIL-F-21572 (Wep)
3.4.1.6
Electrical Connections - Connections to external circuits shall be provided as
follows:
Receptacle
Reference
Function,
Type
Designation
RF signal inlet
58A5A189-1
J1201
58A6A51
Output receptacle
J1202
Power inlet and outlet to
Ms3102A-28-21P
J1203
control panel
58A5A238-16-26SN
Power inlet and outlet to
J1204
BULL PUP relay box
3.4.2 Oscillator, Radio Frequency O-562/AWW-l - The radio frequency oscillator
shall meet the following requirements:
3.4.2.l Function- The radio frequency oscillator shall supply r-f fuze charging signals
to the amplifier-power supply. The r-f signals, when amplified, shall meet the voltage and
frequency requirements of table I.
3.4.2.2 Form Factor - The dimensions of the radio frequency oscillator shall not ex-
ceed 3 1/2 inches wide by 4 5/16 inches high by 4 5/8 inches long.
3.4.2.3 Weight - The weight of the radio frequency oscillator shall not exceed 1 3/4
pounds.
3.4.2.4 Contents of Unit - The radio frequent y oscillator shall contain four oscillator
circuits with replaceable and interchangeable plug-in type tuned circuits. There shall be eight
plug-in units which shall provide the frequencies specified in table I.
3.4.2.5 Controls - The radio frequency oscillator shall contain four screwdriver adjusted
controls (one for oscillator circuit). The controls shall be used to adjust the amplitude of
the r-f signal outputs. The controls shall be located on the side of the radio frequency oscillator
and shall be labeled R1301 through R1304 respectively.
3.4.2.6 Electrical Connections - Connections to external circuits shall be provided as
follows
Receptacle
Reference
Function
Type
Designation
DC inlet and RF outlet
58A5A189-2
JI3O1
Control, Fuze Function C-2612/AWW- 1- The fuze function control shall meet the
3.4,3
applicable requirements of Specification MIL-C-6781 for Type I control panels.
3.4.3.1 Function- - The fuze function-control shall be used to select the available d-c and
r-f fuze charging options.
3.4.3.2 Form Factor - The maximum dimensions of the fuze function control shall not
exceed 5 3/4 inches wide by 3 inches high by 6 1/16 inches long.
.
3.4.3.3 Weight - The weight of the fuze function control shall not exceed 2.0 pounds.
3.4.3.4 Controls - The fuze function control shall contain the following operating controls
on the front panel.
|