MIL-F-21572(Wep)
(1) SAFE - STBY - READY Switch -  This 3-position rotary switch shall be used to
control the power applied to the fuze function control set. The switch positions shall be
labeled SAFE, STBY, and READY respectively.
(2) OPTION SELECTOR Switch - This 8-position rotary switch shall be used to select
the various d-c and r-f fuze charging options available in the fuze function control-set. The
switch shall be labeled OPTION SELECTOR, and the switch position shall be labeled A through
H respectively.
.
(3) PRESS TO TEST Switch - This spring-loaded push button switch shall be used to
check the system for readiness. The switch shall be labeled PRESS TO TEST.
3.4. 3.5 Electrical Connections - Connections to external circuits shall be provided as
follows:
Reference
Receptacle
Designation
Type
Function
MS3102A- 28- 21P
Outlet to amplifier-power supply
J1601
58A5A238-14- 19PN
J1602
Power inlet and BULL PUP connection
3.4.3.6 Panel Illumination Lamps - When + 28 volts d-c is applied between pins p and b
.--.
of J1 601, lamps 11601 and 11602 shall light.
3.4.3.7 HV D. C. CHECK Lamp - When+ 300 volts d-c is applied between pins K and b
of J1601, and the PRESS TO TEST switch is pressed, lamp 11603 shall light.
4.
QUALITY ASSURANCE PROVISIONS
4.1 General - Items covered by this specification shall be subjected to the following tests
to determine compliance with all applicable requirements:
(l) Preproduction Tests
(2) Production Sample Tests
(3) Acceptance Tests
(4) Life Tests
4.2 Preproduction Tests - Preproduction tests shall be made on one or more equipments
representative of the production equipments to be supplied under the contract. Preproduction
tests shall consist of the following:
(1) Contractor's Demonstration Tests
(2) Service Approval Tests
4.2.1
Contractors Demonstration Tests - Contractor"s demonstration tests shall be ac-
of the contractor and shall be conducted in accordance with
complished under the responsibility
the approved test procedure of 4.6.  Data obtained by the contractor in conducting these tests
shall be submitted to the procuring activity for review and approval prior to shipping the equip-
ment to the specified destination for service approval tests. The government inspector and the
procuring activity shall be advised when tests are to be conducted so that a representative may
be designated to witness or supervise the tests when so desired. Contractors not having ade-
quate facilities to conduct all required tests shall obtain the service of a commercial testing
laboratory satifactory to the procuring activity.