MIL-F-24702(SH)
5.2.2 Level C.
Preservation shall be as specified for level A except:
(a) The unit protection shall be by method IC-3, bag closure accomp-
lished by twist-tie with plastic clips or plastic coated ties,
and the leak and heat-seal tests are not required.
(b) The unit containers specified in 5.2.1.2 shall be of the
domestic/fire retardant or non-weather resistant type, class or
variety.  Method I using pressure-sensitive tape shall apply for
fiberboard box closure.
5.2.3 Commercial.  Commercial packaging (cleaning, preservation, cushioning
and unit pack) requirements shall be in accordance with ASTM D 3951.
5.3 Packing.  Packing when required (see 6.2.1), shall be level A, B, C, or
commercial as specified (see 6.2.1).
5.3.1 General require ments for levels A, B, and C.  Containers selected
(see 5.3.2) shall be of minimum weight and cube consistent with the protection
required, of uniform size, and contain identical quantities of identical filter
elements.
5.3.2  Levels A, B, and C containers.  Filter elements preserved as speci-
fied (see 5.2) shall be packed in exterior shipping containers for the level of
packing specified (see 5.3), in accordance with MIL-STD-2073-1.  Unless otherwise
specified (see 6.2.1), container selection shall be at the contractor's  option.
5.3.2.1 Caseliners, closure and gross weight.
5.3.2.1.1 Caseliners.  Unless otherwise specified (see 6.2.1), level A
shipping containers containing filter elements preserved level C or commercial
shall be provided with waterproof caseliners in accordance with MIL-STD-2073-1.
5.3.2.1.2 Closure.  Container closure, reinforcing, or banding shall be in
accordance with the applicable container specification or appendix thereto except
that weather-resistant fiberboard boxes shall be closed in accordance with method
V and reinforced with nonmetallic or tape banding and domestic or fire retardant
fiberboard boxes shall be closed in accordance with method I using pressure
sensitive tape.
5.3.2.1.3 Weight.  Wood, plywood, and cleated type containers exceeding 200
pounds gross weight shall be modified by the addition of skids in accordance with
MIL-STD-2073-1 and the applicable container specification or appendix thereto.
5.3.3 Commercial.  Filter elements preserved as specified (see 5.2) shall
be packed for shipment in accordance with ASTM D 3951 and herein.
5.3.3.1 Container modification.  Shipping containers exceeding 200 pounds
gross weight shall be provided with a minimum of two, 3- by 4-inch nominal wood
skids laid flat, or a skid- or sill-type base which will support the material and
facilitate handling by mechanical handling equipment during shipment and storage.
5 4 Palletized unit loads.  When specified (see 6.2.1), containers shall be
palletized in accordance with MIL-STD-2073-1.
12

Privacy Statement - Press Release - Copyright Information. - Contact Us