| MIL-F-26301F
TABLE II. First article inspection.
Inspection
Requirement
Test
Number of
Number of
paragraph
paragraph
sample flashers
allowable
to be inspected
failures
Group I
Visual and mechanical
3.1, 3.3, 3.4, 3.18,
4.4.1
examination (external)
and 3.19
All flashers in
1
sample
(13 total 1/ )
Flash characteristics
3.5.4
4.4.2
Voltage drop
3.6
4.4.3
Group II
High and low temperature
3.7
4.4.4
soak and operation.
3
1
Vibration
3.8
4.4.5
Immersion
3.9
4.4.6
Group III
Shock
3.10
4.4.7
Altitude
3.11
4.4.8
Humidity
3.12
4.4.9
3
1
Salt fog
3.13
4.4.10
Sand and dust
3.14
4.4.11
(when specified)
Group IV
Electromagnetic interference
3.15
4.4.12
2
0
Transient voltage
3.16
4.4.13
Group V
Life
3.17
4.4.14
4
0
1/ One additional flasher is included in the sample to allow for the one defective flasher allowed for group I.