| MIL-F-48057B (AR)
AMENDMENT 7
force shall act against the lever. Upon removal of the
required force, the maximum permissible gap shall be inspected
for compliance with the drawing requirement. Any lever shaft
that fails the requirement shall be classed defective and
removed from the lot."
PAGE 55
4.5.10:
Delete in its entirety.
PAGE 56
4.5.10: Delete paragraph starting with "Defect standards ..."
from para 4.5.10 and add it to para 4.5.11.2.1.
4.5.11.1: Delete last four lines and substitute "specified "g"
limits for the arming tests are reached. This test equipment,
if housed within a temperature conditioning chamber, shall be
capable of operation between -40F and +160F with a
tolerance of 5F. The acceleration tolerance shall be
.10g. Timemeasuring equipment shall be accurate within
0.01 second."
4.5.11.2.1: Delete "containing a power supply striker and spring
but no explosives" and substitute "completely assembled".
4.5.11.2.2: Delete in its entirety, except for title, and
substitute "The device completely assembled shall be placed in
the centrifuge and tested at 12g for five seconds. The device
shall be tested in a spring-loaded fixture which simulates the
MIG spring. The device shall meet the requirements of 3.3.1.
Any S&A that fails to meet the requirement shall be classed
defective."
4.5.11.3:
Delete in its entirety.
4.5.11.4: Delete "4.5.11.2.1 or 4. 5.11.2.2 except that the" and
substitute "4.5.11.1. The".
PAGE 57
4.5.11.5: Delete "4.5.11.2.1 or 4.5.11.2.2 except that the" and
substitute "4.5.11.1. The".
Add "and removed from the lot" to last sentence.