| NOTE 2. - In establishing a curing time, dimensionally check ten
(10) parts from each cavity at periodic intervals (e.g. every
30, 60, etc. reins.) until dimensional stability is attained. The
curing time will be from the time the part comes out of the mold
The inspection data used
until dimensional stability is attained.
in determining the curing time shall be sent to Picatinny Arsenal,
Dover, New Jersey, 07801 ATTN: SMUPA-QA-A-M. If any new change l
in material, cycle time, a reworked cavity, or a new cavity is
used, a new curing time shall be established and approved.
4.3.5.1 Connector assembly, male (see dwg. 9272095 covering
a detail of dwg. 9270787).
Minor:
None Defined
4.3.5.2 Case, right hand (see dwg. 9270795 covering a detail
of dwg. 9270787).