| MIL-F-48673 (AR)
Temperatur e,/altitude test equipm ent
TABLE
VIII.
Cal
ibr at i on
Type/Model
Range/Accuracy
Description
period
0
Hieatt/THV-27
As Req'd
-80 to +200 /~2C
Temperature/Altitude
Chamber and Recording
- lK to +1OOK feet/~5%
As Req'd
S top Natch
Minerva
0-50 sees/mins/+0. 1%
0
Honeywell/
-1oo to +200 F
Multi-point
Temperature e Recorder
Ekectroni k 16
+~1 . 2oF
As Req'd
453
Oscilloscope
0-5 MHz + 3%
As Req'd
CA
Vertical Amp Plug in
DC -24MHz 23%
Facility
N/A
Electrical Power
115 vac, 60 Hz
10, 30A
As Req'd
HP/6266A
Power Supply, DC
0-36 volts/5amps
4. 8.1.2.4 Temperature/altitude test methods of inspe ction
q
4. 8.1.2.4.1 Test performance. The chamber air will be
,
controlled to the specified ambient temperatures with all temperatures
monitored and recorded. With the FCC-FTS placed in the temperature/
altitude chamber and connected as specified in paragraph 4.5.2.1.5?
determine initial conditions as outlined in 4.5.2.1.6.2.
4. 8.1.2.4.2 Standard conditions (reference) . With the chamber
door open and the FCC-FTS exposed to room ambient conditions, the
FCC-FTS shall be turned on and operated in accordance with the
functional tests of paragraph 4.7. The functional performance of the
FCC-FTS shall be checked with warmup times not exceeding 10 minutes
and the input voltages to the FCC-FTS set at:
a.
Nominal 28 VDC
High 30.8 VDC
b.
Low 25.2 VDC
C.
I
I
The multi-point temperature recorder shall be on and recording the
chamber wall and air temperatures and the thermally instrumented
component temperatures wi thin the FCC-FTS throughout all temperature/
altitude tests. Record the results of the above tests on the
applicable data sheets.