| MIL-F-48673 (AR)
The test item
energized only a sufficient time to allow
shall be
the required warmupd
measurements specified in the equipment
specification.
9. After completion of the fifth cycle with the test item in
the chamber and the chamber at 30 + 5C (860 + 9oF) and a
relative humidity of not less than 95%, take measurements specified
in the equipment test data sheets.
.
o
o
h. Condition the test item at 250 + 5 C (770 + 9 F) and
50 + 5 percent relative humidity for not less than 12 hours nor more
than 24 hours.
While at 25 +
(770 + 9F) and 50 percent
i.
relative humidity, take measurements as specified in the equipment
test data sheets.
Inspect test item to detect evidence of physical degradation
j.
(such as corrosion of metal parts, distortion of plastic parts, and
when visible corrosion
insufficient lubrication of moving parts).
is removed by suitable Cleaningr tbe equipment shall, as a result of
the cleaning, be returned to a condition which conforms to the
requirements of preoperational inspection and the performance of
the equipment shall not be degraded.
4. 8.1.3.4.2 Post humidity operation. At the completion of the
five humidity cycles, the FCC-FTS shall be removed from the humidity
chamber and subjected to the post operational performance tests in
accordance with paragraph 4S6.2 of this procedure as soon as
possible, but not later than one hour after completion of the
humidity test. Prior to measurements, excess moisture may be
removed frm the exterior surfaces of the FCC-FTS by turning the
unit upside down or by wiping the external surfaces only. Record
the results of this test on the applicable data sheet.
4. 8.1.3.4.3 Moisture test. Following the above check for
satisfactory operation the FCC-FTS shall be opened and examined for
evidence of entrapped moisture. Record the results of this
examination on the applicable data sheet.
4.8.1.4 Vibration. FCC-FTS shall be subjected to the category
(h) and (g) tests required by MIL-STD-81O and MIL-T-28800. The
applicable tests are listed in Table XI-
46
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |