MIL-F-48673 (AR)
Test facility.
4. 8.1.4.1
The  vibration  tests  shall  be
a.
Vibration  exciter  system.
q
performed on a vibration  exciter  system  capable  of  shaking  the
Transverse
FCC-FTS  at  the  specified  amplitudes  and  frequencies.
action  of  the  exciter  (unloaded)  shall  be  less  than  20  percent  of
the input motion and the hUarmonic wave distortion  of  the  fundamental
frequency shall not exceed 10 percent.
Vibration
tests
TABLE
XI.
Test Conditions
Resonant  Search  5-55  Hz  (each  of
1.
3  axes)  non-operating  (2  increments)
Resonant Dwell (each of 3 axes)
2.
non-operating
Sinusoidal Cycling 5-55 Hz (each of
3.
3 axes) non-operating :
b.  Accelerometer , control.  The accelerometer used to measure
and control the input acceleration to the test specimen shall be
rigidly attached to the base plate of the test specimen vibration
fixture, using the stud normally supplied or by cementing in place
using Eastman 910 or dental adhesives.  The accelerometer shall be
positioned as close as possible to the attachment points of the
TCC-FTS to the fixture.  The frequency response of the control
accelerometer should be flat within +  5%, 5 Hz to 3 KHz at room
ambient temperature.
Test fixture.  The holding fixture for the FCC-FTS hshall it
co
simulate the normal installation as nearly as possible.  T at is
shall have, 1) provisions for attachment of its base plate directly
to the vibration exciter head or the horizontal slip table, and 2)
provisions for the rigid attachment of the FCC-FTS to the base plate.
4.8.1.4.2 Vibration test equipment.  The test equipment listed
in Table XII will be required to conduct the vibration tests.  All
measurements shall be made with instruments whose accuracy and
calibration has been verified periodically and meet specification
requirements.