| MIL-F-50532A(MI)
Defects
Method of
Code No.
Categories
Inspection
AQL 0.65 percent
Minor:
201.
Evidence of poor workmanship
(see 3.11) . . . . . . . . . . . . . . . . . . Visual
02004
4.3.2.3 Spring, rotor (see dwg. 10048581 covering a detail of dwg.
9252817).
Method of
Code No.
Defects
Categories
Inspection
Critical: None defined.
AQL 0.65 percent
Major:
101.
Torque improper at either or both
03001
angular displacements . . . . . . . . . . . . . Gage
03002
102.
Inside diameter, min . . . . . . . . . . . . . Gage
03003
Solid height, maximum (max. )........ Gage
103.
Protective finish incomplete or
104.
03004
inadequate . . . . . . . . . . . . . . . . . . . . Visual
AQL 0.65 Percent
Minor:
201.
Evidence of poor workmanship
03005
(see 3.11) . . . . . . . . . . . . . . . . . . . Visual
4.3.2.4 Spring, firing pin (see dwg. 8796380 covering a detail of dwg.
9252815).
Categories
Defects
Method of
Code No.
Inspection
None defined.
Critical:
Major:
AQL 0.65 Percent
101.
Solid height, max . . . . . . . . . . . . Gage
04001
102.
Load at assembled height . . . . . . . . . . . Gage
04002
103.
Protective finish incomplete or
inadequate. . . . . . . . . . . . . . . . . Visual
04003
Minor:
AQL 1.00 percent
201.
Ends not ground. . . . . . . . . . . Visual
04004
202.
Evidence of poor workmanship . . . . .Visual
04005
(see 3.11)