| MIL-F-50532A(MI)
4.3.2.5 Pin, firing (see dwg. 8796383 covering a detail of dwg. 9252815)
Code No.
Method of
Defects
Categories
Inspection
None defined.
Critical:
Major:
AQL 0.65 percent
Profile of firing pin point. , . . . . . . . Gage
05001
101.
05002
Outside diameter, min . . . . . . . . . . . . . . . Gage
102.
05003
103.
Inside diameter, max . . . . . . . . . . . . . . . . Gage
104.
Protective finish incomplete or
inadequate . . . . . . . . . . . . . . . . . . . Visual
05004
AQL 1.00 percent
Minor:
201.
Concentricity of inside diameter
05005
with outside diameter . . . . . . . . . . . . . . . Gage
202.
Evidence of poor workmanship. .
05006
(see 3.11 ) . . . . . . . . . . . . . . . . . . Visual
4.3.2,6 Leaf No. 1 (see dwg.
8796408 covering a detail of dwg. 10048781).
Defects
Code No.
Method of
Categories
Inspection
Critical:
None defined.
AQL 0.40 percent
Major:
Plating on inside diameter of
101.
06001
hole incomplete or damaged . . . . . . . .Visual
06002
Finish improper . . . . . . . . . . . . . . . Visual
102.
AQL 0.65 percent
Minor:
201.
Evidence of poor workmanship
06003
(see 3.11) . . . . . . . . . . . . . . . . . . . . . . Visual
4.3.2.7 Leaf No. 2 (see dwg.
8796410 covering a detail of dwg. 10048781.
Code No.
Method of
Defects
Categories
Inspection
Critical:
None defined.
Major:
AQL 0.40 percent
101.
Plating in inside surface of
hole incomplete or damaged . . . . . . . . . . . Visual
07001
102.
Finish improper . . . . . . . . . . . . . . . . . . . . . Visual
07002