| MIL-F-50532A(MI)
Categories
Defects
Method of
Code No.
Inspection
Finish improper . . . . . . . . . Visual
102.
10002
Minor:
AQL 0.65 percent
201.
Evidence of poor workmanship
(see 3.11) . . . . . . . . . . . . . . . . . . . . . . . . . . . Visual
10003
4.3.2.11 Base, mounting (see dwg. 10048784 covering a detail of dwg.
10048785).
Categories
Defects
Method of
Code No.
Inspection
Critical:
None defined.
Major:
AQL 0.65 percent
101.
Height to cover seating
surface, min . . . . . . . . . . . . . . . Gage
11001
102.
Height to top of cylindrical
11002
portion of base, max . . . . . . . . . .Gage
Finish of firing pin cavity
103.
improper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Visual
11003
Finish of locking shaft cavity
104.
improper . . . . . . . . . . . . . . . . . . . . . . . . . . . . Visual
11004
Minor:
AQL 0.65 percent
201.
Evidence of poor workmanship
11005
(see 3.11) . . . . . . . . . . . . . . . . . . Visual
4.3.2.12
Setback assembly (see dwg.
10048781 covering a detail of dwg.
9252817).
Categories
Method of
Code No.
Defects
Inspection
Critical:
1. Stud leaf No. 1 and/or stud leaf No. 2
12001
not peened secure . . . . . . . . . . . . . . . . . . . . . . . Visual
*
2. Electrical resistance between setback
support and telltale inner contact
(see 3.5.1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Test (see 4.4.6) 12002
3. Distance between the front surface of the
set back support and the rear surface of
leaf number 1 above, max . . . . . . . . . . . . . Gage
12003
13
|