| MIL-F-50532A(MI)
Method of
Defects
Categories
Code No.
Inspection
AQL 0.65 percent
Major:
Telltale inner contact loose or
101.
deformed. . . . . . . . . . . . . Visual/Manual
12004
102.
Telltale insulator projects beyond
aft surface of telltale inner contact . . . Visual
12005
103.
Plating damaged (other than peened
12006
students). . . . . . . . . . . . . . . . . . Visual
104.
Assembly incorrect or incomplete . . . . . . . . Visual
12007
AQL 0.65 percent
Minor:
12008
201.
Evidence of poor workmanship (see 3.11 ).. Visual
4.3.2.13 Rotor assembly (see 9252818 covering a detail of dwg. 9252817).
Method of
Categories
Defects
Code No.
Inspection
Critical:
13001
1. Push test of rotor pin.... . . . . . . . . . . . . . . . . Test
Major:
AQL 1.00 percent
101. Plating damaged other than stake marks . . . Visual
13002
13003
102. Detonator washer improperly staked . . . . . . . Visual
13005
104. Rotor gear improperly staked . . . . . . . . . . . . . Visual
106. Flash hole between primer cavity and
13007
detonator cavity obstructed . . . . . . . . . . . . . . Visual
13008
107. Components missing or loose . . . . . . . . Visual/Manual
Minor:
AQL 0.65 percent
13009
201. Evidence of poor workmanship (see 3.11) . . . . Visual
4.3.2.14 Base plate and rotor assembly (see dwg. 9252817 covering a detail
of dwg. 9252815).
Method of
Code No.
Defects
Categories
Inspection
Critical:
None defined.
AQL 1.00 percent
Major:
Primer inverted or loose . . . . . . . . . . . . . Visual/Manual
14001
101.
102.
Staking inadequate or improperly
. . . . . . . . . . . . . . . . . . . . . . . . . . . . Visual
14002
14003
103.
Components missing or damaged . . . . . . . . . . . . Visual
14
|