| MIL-F-50532A(MI)
2.
Electrical Test mark missing
(telltale contact-cover) . . . . . . . . . . . Visual (see 4.4.5)16002
3.
Rotor in armed or partially
armed position . . . . . . . . . . . . . . Visual (see 4.4.5) 16017
AQL 0.40 percent
Major:
16003
101.
Base plug loose or above flush . . . . . . Manual/Manual
16004
Assembly dented or damaged . . . . . Visual
102.
Minor:
AQL 1.00 percent
201.
Marking incorrect, incomplete,
illegible or missing . . . . . . . . . . . . . . . . Visual
16005
202.
Evidence of poor workmanship
(see 3.11) . . . . . . . . . . . . . . . . Visual
16006
4.3.2.17 Cup, (see dwg. 9252743 covering a detail of dwg. 9240943).
Method of
Defects
Code No.
Categories
Inspection
Critical:
17001
1. Split or cut . . . . . . . . . . . . . . . . . . . . . Visual
AQL 0.65 percent
Major:
17002
Thickness through bottom, min . . . . . . . Gage
101.
Outside diameter, max . . . . . . . . . . . . . . . Gage
17003
102.
17004
Dent or distortion . . . . . . . . . . . . . . . . . . Visual
103.
AQL 1.00 percent
Minor:
17005
201.
Inside diameter, min . . . . . . . . . . . . . . . . Gage
202.
Evidence of poor workmanship
17006
(see 3.11 ) . . . . . . . . . . . . . . . . . . . . . . . Visual
4.3.2.18 Plug (see dwg. 9252737 covering a detail of dwg. 9240943).
Method of
Defects
Code No.
Categories
Inspection
None defined.
Critical:
Major:
AQL 0.40 percent
18001
Outside diameter, min . . . . . . . . . . . Gage
101.
18002
102.
Diameter of sleeve surface, min . . . . . Gage
Minor:
201.
Evidence of poor workmanship (see 3.11) Visual
18003
16
|