| MIL-F-50532A(MI)
Method of
Defects
Code No.
Categories
Inspection
104.
Rotor slot not clinched over
14004
rotor spring . . . . . . . . . . . . . . . . . . Visual
105.
Retaining spring improperly positioned
damaged, and/or not under tension
14005
(see dwg. 10048785 ) . . . . . . . . .. Manual . .. Visual/Manual
Protruding burr in primer
106.
14016
staking area. . . . . . . . . . . . . . . . . Visual
AQL 0.65 percent
Minor:
201.
Evidence of poor workmanship
(see 3.11 ) . . . . . . . . . . . . . . . . . Visual
14006
4.3.2.15 Cover assembly (see dwg. 9252816 covering a detail of dwg. 9252815).
Code No.
Categories
Defects
Method of
Inspection
Critical:
1.
Electrical resistance between
telltale rivet and cover (see
15001
3.5.2) . . . . . . . . . . . . . . . . . . . . . . . Test (see 4.4.4)
Major:
AQL 1.00 percent
101.
Cup not concentric with outside
diameter of cover . . . . . . . . . . . . Gage
15002
102.
Cover plage not concentric with
15003
outside diameter of cover. . . . . . . . . . . . . Gage
Flash hole obstructed by excessive
103.
15004
brazing material . . . . . . . . . . . Visual
Plating incomplete or inadequate . . . . Visual
104.
15005
15006
Telltale rivet loose . . . . . . . . . . . . . . . Manual
105.
Minor:
AQL 1.50 percent
15007
Depth of cup, min . . . . . , . . . . . . . . . Gage
201.
Window(s) damaged obscuring vision . . Visual
202.
15008
15009
Evidence of poor workmanship (see 3.11) Visual
203.
4.3.2,16 Fuze, Rocket, BD XM434, prior to assembly of primer cord (see
dwg. 9252815).
Categories
Defects
Method of
Code No.
Inspection
Critical:
1.
Fuze in the armed or partially
armed position (see 3.5.3) . . . . . . . . . . . Test (see 4.4.5)
16001
15
|