| MIL-F-50532A(MI)
4.3.2.22 Assembly, Plug Loading (see dwg. 9252739 covering a detail of
dwg. 9240943).
Code No.
Method of
Defects
Categories
Inspection
Critical:
22001
1. Explosive on exterior . . . . . . . . . . . . Visual
AQL 0.40 percent
Major:
22002
101.
Priming charge missing . . . . . . . . . . . Visual
AQL 0.65 percent
Minor:
Evidence of poor workmanship
201.
20003
(see 3.11) . . . . . . . . . . . . . . . . . . . . Visual
4.3.2.23 Detonator Assembly (see dwg. 9240943 covering a detail of dwg.
9252818).
Code No.
Method of
Defects
Categories
Inspection
Critical :
23001
1. Cup split or cracked . . . . . . . . . . . . . . . . . . Visual
AQL 1.00 percent
Major:
23002
Plug cracked . . . . . . . . . . . . . . . . . . . Visual
101.
23003
Total length, max. . . . . . . . . . . . . . . Gage
102.
23004
103.
Diameter of cup at plug end, max . . . . Gage
23005
104.
Crimp not full 360 degrees . . . . . . Visual
23006
Varnish missing or inadequate . . . . . . . Visual
105.
AQL 1.00 percent
Minor:
23007
Diameter of cup at charge end, max . . Gage
201.
202.
Evidence of poor workmanship
23008
(see 3. 11 ) . . . . . . . . . . . . . . . . . Visual
4.3.2.24 Carton, packing (see dwg. 8798862).
Code No.
Method of
Defects
Categories
Inspection
None defined.
Critical:
AQL 0.40 percent
Major:
Sealing strip loose, torn, incomplete,
101.
24001
wrinkled, or improperly adhered . . . . . Visual
18
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |