MIL-F-50532A(MI)
Minor:
AQL 1.50 percent
201.
Contents move when shaken . . . . . . . . . . Manual
24003
202.
Label missing. . . . . . . . . . . . . . . Yisual
24004
203.
Marking incorrect, incomplete,
illegible, or missing . . . . . . . . . . . . . . . Visual
24005
4.3.2.25 Box, packing (see dwg. 8798863).
Categories
Defects
Method of
Code No.
Inspection
Critical:
None defined.
Major:
AQL 0.65 percent
101.
Top improperly assembled . . . . . . . . . . . . Visual/Manual
25001
102.
Board broken or split . . . . . . . . . . . . Visual/Manual
25002
103.
Strapping missing, broken or loose . . Visual/Manual
25003
104.
Contents exposed . . . . . . . . . . . . . . Visual
25004
Minor:
AQL 1.00 percent
201.
Contents loose . . . . . . . . . . . Manual
25005
202.
Marking misleading or unidentifiable. . Visual
25006
4.3.3 Testing
4.3.3.1 First article sample (see 4.2.1).
The samples submitted as the
first article quantity shall be tested as specified herein after being examined
100 percent for the applicable classifications of defects in paragraph 4.3.2.
4.3.3.1.1 Solid firm lubricant (see dwg. 8796419, 8796420 and 10048602) -
Major defect - Star Wheel - CodeNo.26001; Pallet - Code No. 26002; and
Pinion gear - Code No. 26003. A sample of 15 of each component shall
Rejection
selected for the first article and tested as specified in 4.4.1.
shall be as specified in 4.2.3.
4.3.2.1.2 Spring embrittlement (see 3.3). Critical defect - Spring leaf
No. 2 - Code No. 01005; Spring leaf No. 3 - Code No. 02005; Major defect -
Spring rotor - Code No. 03006 and and Spring firing pin - Code No. 04006. A sample
of 15 springs shall be selected of each spring type for the first article and
tested as specified in 4.4.2. Rejection shall be as specified in 4.2.3.
4.3.3.1.3 Porosity and surface finish of mounting base (see 3.4 and dwg.
10048784) - Porosity - Major defect - Code No, 11006; Surface finish - Major
defect - Code No. 11007. A sample of 15 mounting bases shall be selected
for the first article and tested as specified in 4,4.3. Rejection shall be
as specified in 4.2.3.
19