MIL-F-81966(AS)
- The output shall be within +0.5 volt of 3.4.2.3
c. INST Position
d. DLY 1 Position - The output shall be within +0.5 volt of 3.4.2.4
3.4.3.2 with an operating power input of high line voltage and low line
frequency, the power supply output shall be as specified in 3.4.3.1 a, b, c, and d.
3.4.3.3 With an operating power input of low line voltage and high line
frequency, the power supply output shall be as specified in 3.4.3.1 a, b, c, and d.
3.4.3.4 With an operating power input of high line voltage and high line
frequency, the power supply output shall be as specified in 3.4.3.1 a, b, c, and d.
3.4.4 Recovery Time at Standard A-C Operating Power under Varying Loads -
,
3.4.4.1 VT Position [MK-344} - With the Fuze function Control switch in the VT
position, the output voltage shall recover to within 3.0 volts d-c of the no-load
value within 6 milliseconds after application of a simulated 6 fuze {MK-344) load
shown in figure 2B.
3.4.4.2 INST Position MK-344) - With the Fuze Function Control switch in the
INST position, the output voltage shall recover to within 2.0 volts d-c of the
no-load value-within 4 milliseconds after application of a simulated 6 fuze (Mk-344)
load shown in figure 2B.
3.4.4.3 VT Position (Mk-344) - Repeat 3.4.3.1 except that the load (1 fuze
Mk-344) shall be as shown in figure 2A and the output voltage shall recover to
within 3.0 volts d-c of the no-load value within 1 millisecond.
3.4.5 Recovery Times Under Varying Loads at Extreme Limits of A-C Operating
Power Inputs -
3.4.5.1 Repeat 3.4.4.1 through 3.4.4.3 except that the a-c operating power
input shall be as follows:
a. Low line voltage and low line frequency
b. High line voltage and low line frequency
c. Low line voltage and high line frequency
d. High line voltage and high line frequency
3.4.6 Output Voltage Under Constant Load at Standard Op erating Power Input -
3.4.6.1 VT Position - With the Fuze Function Control switch in the VT position,
the output shall be within + 1.5 volts of 3.4.2.1 at 25 + lOC when a 1000 + 10 ohms
load is applied.  At all other temperatures the output shall be within + 3.O volts of
.-.
.
3.4.2.1.
3.4.6.2 INST Position - With the Fuze Function Control switch in the INST
position, the output shall be within + 1.0 volts of 3.4.2.3 at 25 + 10C when a 1000
+ 10 ohms is applied.  At all other temperatures the output shall be within + 2.O
volts of 3.4.2.1.