| ![]() MIL-G-50960(MU)
Major:
101. Outside diameter . . . . . . . . . . . . . . . . . . . . . . .Gage
102. Thickness . . . . . . . . . . . . . . . . . . . . . . . . . . .Gage
103. Inside diameter . . . . . . . . . . . . . . . . . . . . . . . Visual
104. Materia1 (see 3.1) . . . . . . . . . . . . . . . . . . . . . . Visual
105. No tearS, cracks or holes in gasket . . . . . . . . . . . . .Visual
Minor:
201. Workmanship (see 3.3) . . . . . . . . . . . . . . . . Visual/Manual
4.3.2.1.2 Preparation for delivery (see 5.1) .
Method of Inspection
Characteristics
Categories
Critical: None defined.
Major:
101. Preservation, packaging, packing and
marking in accordance with MIL-P-l169(MU) . . Visual/Manual
Minor: None defined.
4.3.2.1.3 Bag, packing, ammunition, for gasket (see dwg.
8848472 covering dwg part nos 8848472-1 or 2 as applicable and 5.)
Method of Inspection
Characteristics
Categories
none defined.
Critical:
Major:
101. Material (See 3.1) . . . . . . . . . . . . . . . . . . . . . . Visual
102. Length before Packing, min . . . . . . . . . . . . . **Measure
103. Width before packing, min. . . . . . . . . . . . . . Measure
+
104. Properly packed . . . . . . . . . . . .. . . . . . . Visual/Manual
105. Proper heat seal . . . . . . . . . . . . . . . . . . . . Visual/Manual
106. No crack or hole in bag . . . . . . . . . . . . . . . . . . . . Visual
107. Objective evidence (see 6.2) for heat seal
test in accordance with MIL-P-116 . . . . . . . . . . . . Visual
108. Stiffeners present. . . . . . . . . . . . . . . . . Manual
*Measure with suitable scale.
Minor:
201. Marking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Visual
202. Workmanship (see 3. 3) . . . . . . . . . . . . . . . .Visual/Manual
4
|