| MIL-G-85299(AS)
The requirements are as
(2) Missile audio, W1, P2-15 (W2, P2-19).
specified in 3.4.5.2.a.(10).
No test shall be performed in this
FUNCTION SELECT test three.
c.
operating mode.
FUNCTION SELECT test four.
d.
(1) Manual uncage, W1, P2-25 (W2, P2-25).
(a) A 620 + 5 percent ohms resistive load shall be continuously
applied between ground and input pin W1, P2-25.
(b) The input pin is monitored for correct voltage in accordance
with the accept/reject limits of table IV. The accept/reject
decision is updated at a one Hertz rate.
(2) Left-right reference, W1, P2-34 (W2, P2-23). The requirements are
as specified in 3.4.5.2.d.(1).
(3) Acquisition lambda, W1, P2-5 (W2, P2-21). The requirements are as
specified in 3.4.5.2.d.(2).
(4) Electrical cage return, W1, P2-23 (W2, P2-22). The requirements
are as specified in 3.4.5.2.d.(3).
The requirements are as
(5) Missile audio, W1, P2-15 (W2, P2-19).
specified in 3.4.5.2.d.(4).
The requirements are as
(6) Fire signal, W1, P2-13 (W2, P2-1).
specified in 3.4.5.2.a.(7).
3.4.5.4 Built-in-test requirements.
a.
Common requirements.
(1) Built-in-test (BIT) reject status shall be indicated by the
flashing of the SELECTED FUNCTION NO-GO front panel lamp at a
rate of 0.5 to 1.3 Hertz.
(2) BIT reject status indication shall be overridden when the
FUNCTION SELECT switch is in the TD position.
(3) All BIT accept/reject limits shall be as specified in Drawing
1058AS11OO.
Power supply BIT.
b.
(1) For FUNCTION SELECT positions one through four, the BIT shall
check all internal regulated power supply voltages and the DVM
reference voltage against the +10 volt reference.
(2) For FUNCTION SELECT position four, the amplitude of the
acquisition lambda signal shall also be checked.
18
|