MIL-H-12732E
Samples selected in accordance with 4.6.1.2 shall be
4.6.1.3 Examination.
examined  for the following characteristics.  AQL shall be 1.0 percent defective.
Unprotected exterior, unfinished, metal surfaces not coated with
115.
preservative for level A or B.
116.
Removed strainers not preserved as specified for level A or B.
Unit cover not folded and preserved as specified for level A or B.
117.
Unit cover not installed, secured, and preserved as specified for
118.
level C.
Repair parts not preserved in accordance with the referenced document
119.
for level A or B.
Maintenance tools nor preserved in accordance with the referenced
120.
document for level A or B.
121
Technical publications not preserved as specified for level A, B, or C.
122.
Comparator and accessories not preserved as specified for level A, B,
or C.
123.
Consolidation not preserved as specified for level A, B, or C.
124
Packing not as specified for level A, B, or C.
125.
Strapping not as specified for level A, B, or C.
126.
Marking missing, illegible, incorrect or incomplete.
5.
PACKAGING
5.1 Preservation.
Preservation shall be level A, B, or C as specified (see
6.2).
5.1.1 Level A.
Interior surfaces of the unit shall not require
5.1.1.1 Hypochlorination.
preservation.
Before any surfaces are coated with any preservative(s), they
shall be cleaned and dried in accordance with MIL-P-116.
Exterior unpainted
metal surfaces requiring the application of a contact preservative in accordance
with MIL-P-116 shall be coated with type P-1 preservative.  The provision of
MIL-P-116 snail apply when selecting and determining the applicability of pre-
servatives,
Preservatives specified herein by "P" numbers shall conform to the
applicable specifications listed in MIL-P-116 and shall be applied in accordance
with MIL-P-116.
5.1.1.1.1 Strainer.  Each strainer removed from a chemical hose shall be
preserved in accordance with MIL-P-116, method IC-3.
5.1.1.1.2 Cover.  The unit cover shall be neatly and compactly folded and
preserved in a close-fitting box conforming to PPP-B-636, W6C or W5C.
Repair parts shall be preserved in accordance with
5.1.1. 1.3 Repair parts.
the level A requirements of MIL-R-196.
Parts not specifically mentioned therein
shall be preserved as specified for parts of similar design and construction.
5.1.1.1.4 Maintenance tools.  Maintenance tools shall be preserved in
accordance with PPP-P-40, level A.