5.1. 1.1.5 Technical publications.
Technical publications shall be preserved
in accordance with MIL-P-116, method lC-3 or "Shrink Wrap" method.
5.1.1.1.6 Comparator.  The comparator and accessories shall be placed in the
carrying case provided and closed tightly.
Then, the carrying case shall be
preserved in accordance with MIL-P-116, method IA-14.  The carrying case shall
be considered as the inner container.
5.1.1.1.7 Consolidation.  Components that will not fit in the accessory box
shall be preserved in accordance with MIL-P-116 together in one or more close
fitting boxes conforming to PPP-B-636, W5C or W6C.
Box contents shall be
cushioned and blocked to prevent movement inside containers.
Unless otherwise specified (see 6.2 and 6.7), preservation
5.1.2 Level B.
shall be as specified for level A, except items preserved in accordance with
MIL-P-116, method IC-3, shall be preserved by method III
However, technical
publications shall be preserved as specified for level A.  All items contained
in fiberboard boxes conforming to PPP-B-636, W5C or W6C, shall be substituted by
boxes conforming to PPP-B-636, type CF, class domestic variety SW, grade 125 or
175.
Each complete unit including all accessory components shall
5.1.3 Level C.
The cover shall be installed
be preserved as necessary to prevent deterioration.
on the unit arts secured.  Components which cannot be stowed in the accessory box
...
snail be consolidlated in a fiberboard box in accordance with PPP-E636.
Technical publications shall be preserved in accordance with MIL-P-116 method
IO-3 or "Shrink Wrap method
Packing shall be level A, B, or C as specified (see 6.2).
5.2
Packing.
5.2.1<91
Level A.  Each complete hypochlorinat ion unit including separately boxed
components preserved as specified in 5.1 shall be packed in a close fitting box
Blocking and cushioning
conforming to PPP-B-601, overseas type, style optional.
in accordance with MIL-STD-1186 shall be used as necessary to prevent movement
Strapping shall be conformed to
of contents within the shipping container.
QQ-S-781, class 1, type I or IV, size as applicable, finish B.
5.2.2
Each complete hypochlorination unit shall be packed as spe-
Level B.
cified in 5.2.1 for level A, except that boxes shall be domestic type, and
strapping shall be finish A.
Each complete hypochlorinat ion unit preserved as specified in
5.2.3 Level C.
5.1 shall be packed in a container appropriate for its size and weight.
Marking shall be in accordance with MIL-STD-129.
5.3 Marking.
NOTES
6.
The hypochlorination unit is intended for treating water
6.1 Intended use.
flowing through a pressure main by lnserting the unit in series with the main.