| ![]() MIL-H-62185(AT)
Table V.
Classification of Defects (Cont'd)
Minor Defects AQL 150 Defects/100 Units
Characteristics
Defects
Method of
Inspection
212 Drain valves
Improper assembly installation,
Visual
or control adjustment
213 Cushions, Beats
Improper fit, installation or adhesion
Visual &
rests & crash pads
functional
214 Howitzer travel
Improper assembly or installation
Visual &
lock
functional
215 Traversing and elevating
Improper assembly or installation
Visual &
mechanisms
functional
216 Recoil mechanisms
Improper assembly, installation,
Visual &
replenisher & lines
fluid level and type improper
functional
Improper clearance, assembly,
Visual &
217 Weapon control
installation, circuit identification,
functional
system (includes
panels, solenoids,
protection or markings
switches wiring &
other components)
218 Misc. items, accessories
Improper assembly or installation
Visual &
functional
219 Fire extinguisher
Data card incomplete, improper
Visual
system components
assembly or installation
220 Paint, protective &
Application, coverage and materials
Visual
anti-skid coatings
improper
221 Lube fittings &
Fittings missing, defective
Visual
lubrication
or improperly installed, lubrication
improper
222 Decals, marking data
Incomplete, data, missing, improper
Visual
instruction plates
location or size, illegible