| MIL-I-60166(MU)
4.5.2 Contractor furnished inspection equipment.
4.5.2.1 Contractor design. - The contractor shall design and supply inspec-
tion equipment compatible with the "Test Methods and Procedures" specified in 4.6
and with the "Component Inspection" requirement of Specification MIL-F-13926.
Concept, construction, materials, dimensions, and tolerances used in design of
test equipment shall be so selected and controlled as to insure that the test equip-
ment will permit positive rejection of a product which exceeds the prescribed
tolerance limit, and will reliably indicate acceptability of a product which does not
exceed 90% of the prescribed tolerance limit. Construction shall be such as to
facilitate routine calibration of the equipment.
4.5.2.2 Equipment used for environmental testing. All environmental testing
equipment used to determine compliance with environmental requirements (Listed
below) shall conform to the "Test Facilities" requirements outlined in Specification
MIL-F-13926.
REQUIREMENT
PARAGRAPH
(a)
Vibration
3.5.2
(b)
Temperature
3.4; 3.5.1; 3.8.3.9
(c)
Shock
3.5.3
(d)
Humidity
3.5.5
(e)
Rain
3.5.6
4.6 Test methods and procedures.
4.6.1 Fabrication. - The power inverter shall be subjected to a visual, tactile
and dimensional inspection to determine compliance with the applicable drawings and
requirements of this specification. Dimensional inspection shall be performed using
standard measuring equipment.
4.6.2 Inclosure. - The material and finishes used in manufacture of the inclo-
sure shall be examined to insure compliance with 3.2.1. In addition to visual
examination, data shall be available showing evidence of material analysis prior
to acceptance by certification. The external surfaces of the inverter shall be
visually inspected for completeness of the specified finish and shall show no
evidence of running or color separation, damage, or bare spots as specified in 3.2.1.
4.6.3 Circuit components. - The components used shall be visua1ly examined to
insure compliance with 2.3.3. In addition to view examination, data shall be
available showing evidence of acceptable component manufacture in accordance with
established requirements prior to acceptance by certification.