Page Title: Classification of inspection
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-I-82532(OS)
s u p p l i e r may utilize his own facilities or any commercial laboratory acceptable
t o the Government. The Government reserves the right to perform any of the
i n s p e c t i o n s set forth in the specification where such inspections are deemed nec-
e s s a r y to assure that supplies and services conform to prescribed requirements.
I n s p e c t i o n of the igniter shall be classi-
4.2 Classification of inspection.
fied as follows:
a . Preproduction and periodic production inspection (See 4.5.)
b. Quality conformance inspection (See 4.6.)
4.3 Sampling. (See 6.2.1.)
4.3.1  Lot  size.  T h e term "lot" shall mean "inspection lot"; that is, a
c o l l e c t i o n of product submitted by a supplier for inspection. Unless otherwise
s p e c i f i e d in the contract or order, the number of product in each lot shall be
t h r e e hundred (300).
4 . 3 . 2 P r e p r o d u c t i o n s a m p l e .  A preproduction sample of twenty (20)
i g n i t e r s , manufactured in accordance with 3.2, shall be subjected to the prepro-
d u c t i o n tests detailed in 4.5.  A c c e p t a n c e of the preproduction sample shall be
based on no defects in the sample.  F u r t h e r production of the igniters by the
s u p p l i e r , prior to approval of the preproduction sample, shall be at the supplier's
risk.
4 . 3 . 3 P e r i o d i c p r o d u c t i o n s a m p l e .  F r o m each succeeding lot of three
h u n d r e d (300) or less, a random sample of ten (10) igniters shall be selected.
T h e s e sample units shall be subjected to the tests of 4.5. The igniters shall be
c o n s i d e r e d satisfactory if they meet all specification and pertinent drawing re-
q u i r e m e n t s and withstand the tests specified in 4.5. (See Table I.) When a de-
fective unit is found in any lot, acceptance of all units in the lot shall be withheld
a n d the contractor shall:
D e t e r m i n e the cause of the defect.
a
b . Take the necessary action, with the concurrence of the pro-
c u r i n g activity, to correct or eliminate the defect from all
units in the lot and, if so directed by the procuring activity,
f r o m those units previously shipped.
S u b m i t to the procuring activity for approval, the proposed
c.
c o r r e c t i v e action to prevent recurrence of the defect.
4 . 3 . 4 Q u a l i t y conformance inspection sampling.  S a m p l e s shall be selected
a s specified i n 4.6 and shall be used to determine the acceptability of the igniters
inspected as s p e c i f i e d in 4.6.