3. REQUIREMENTS.
3.1 Conformance with drawings. Unless otherwise specified in the contract, the
igniter shall meet all the requirements specified herein and on the applicable drawings listed
on Dl 1255 AS114.
3.2 First article. When specified in the contract (see 6.2), the contractor shall furnish
sample unit(s) for first article inspection and approval (see 4.4 and 6.4).
3.3 Circuit resistance. The igniter circuit resistance between the ends of the lead
wires shall be between 0.40 and 0.60 ohms (see 4.6.2).
3.4 Performance requirements. The performance requirements of the igniter shall
be as specified in Table I (see 4.6.10). O).
3.5 Environmental requirements.
3.5.1 Impact. The igniter shall withstand the 40-foot drop test without igniting
(see 4.6.3).
3.5.2 Two-foot-drop. The igniter shall withstand the 2-foot drop test without spilling
arty explosive material and without igniting (see 4.6.4).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |